ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Defining Recipe Properties
P/N 97100-9002-000-14 Ver 06/05
5.3-3
2 Select the Recipe from the Programming tree. The properties for the
Recipe are displayed on the right.
3 Double-click the Value cell for each property in turn and enter a value
or select a value from a drop-down list.
4 Click Save . The new Recipe is saved to the System. The System
checks which parameters are required in the Recipe according to the
algorithms selected. If it is found that the Recipe does not include some
of the required parameters, the Missing Parameters Report is
displayed, as follows:
5 Click Close. The missing parameters are added to the Recipe.
Figure 5-4: Recipe Properties
Note: To add a descriptive comment to any Recipe, double-click the
Comments cell and enter the desired text.
Figure 5-5: Missing Parameters Report
Note: The missing parameters are added with their default values, which might
not fit the process program (recipe). Refer to the programming panel to modify