Solution - Print Heads
Troubleshoot using Section 7.3, ’Print Head Errors/ Weak Parts’.
Solution - Motion Problems
• Clean the Fast Axis Rails. See Section 3.4, ’Clean The Fast Axis Rails and Carriage’.
• Clean the Fast Axis Pulleys. See Section 6.6, ’Clean The Fast Axis Pulleys’.
• Clean the Slow Axis Rails and Pulleys. See Section 6.7, ’Clean The Slow Axis Rails and Pulleys’.
7.12 Miscellaneous Problems
7.12.1 Vacuum Has Low/No Suction
Explanation: This is usually an indication that the Debris Separator needs to be emptied and cleaned.
Solution:
• Remove the Debris Separator and empty the contents into a waste receptacle.
• Check that its gasket is not damaged. Also check that all four magnets are in place on the back of the
Separator. These magnets hold the Separator against the panel.
• When you replace the Debris Separator, ensure that it is flush against the panel.
• Check the vacuum hose is not plugged with debris.
• Check that the vacuum hose is not cut or torn.
If, after checking these items the problem persists, contact your Service Provider.