Test Button
All Axis print servers are equipped with a test button. The functionality of the test button is
determined by the number of times the button is being pressed.
• Press the test button once to print a test page that contains basic information about the AXIS
570/670.
• Double-click the test button to print out the current parameter settings of the unit.
You can also reset the AXIS 570/670 parameters to their factory default settings by using the test
button. Follow the instructions below:
1. Remove the external power supply to switch off the AXIS 570/670.
2. Press and hold down the test button, while you reconnect the external power supply. Continue
to hold down the test button until the network indicator starts to flash at one second intervals.
This should take about 5 seconds.
3. Release the test button and wait until the network indicator flashes at least five times.
4. Press and hold down the test button again until the network indicator remains constantly lit.
5. Restart the AXIS 570/670 by switching it off and on.
Note:
All parameters except the node address (NODE_ADDR) and the IP address (IP_ADDR) are reset.