User`s guide

AXIS 5470e/570/670e Users Manual Section 5: Setting Up - IBM Mainframe
73
Local Major
Node Definitions
The example below shows how the print server PU and LU definitions
may be coded in a local major node definition:
Note:
* 5470e DSPU DEFINITION
DSPU5470e PU CUADDR=E31, X
MODETAB=MODE3290, X
PUTYPE=2,ISTATUS=ACTIVE,MAXBFRU=1
DSPULU02 LU LOCADDR=2 X
SSCPFM=USSSCS, X
USSTAB=USSTAB, X
PACING=1, X
VPACING=2, X
ISTATUS=ACTIVE, X
LOGAPPL=MWTC, X
DLOGMOD=SCS5470e
DSPULU03 LU LOCADDR=3, X
SSCPFM=USSSCS, X
USSTAB=USSTAB, X
PACING=1, X
VPACING=2, X
ISTATUS=ACTIVE, X
LOGAPPL=MWTC, X
DLOGMOD=SCS5470e
If the LAN media at the remote (Print Server) location differs from that at the host
location (e.g. Remote LAN = Ethernet and Host LAN = Token Ring), the MAC
address definitions must be modified, as outlined below:
Print Server Modifications:
The AXIS 5470e/570/670e Host MAC address (H1_MAC_ADDR) must be bit-
order reversed for each byte,
e.g. if the host address is 08005AB77D49 the converted address will be
10005AEDBE92