User`s guide

AXIS 5470e/570/670e Users Manual Section 5: Setting Up - IBM Mainframe
71
Switched major
node definitions
The example below shows how the print server PU, PATH, and LU
definitions may be coded in a switched major node definition.
Note:
* PU definition
* E07xxxxxx is the node ID set in AXIS 5470e/570/670e.
*
PU5470e1 PU ADDR=04, X
PUTYPE=2, X
IDBLK=E07, X
IDNUM=nnnnn, X
MAXPATH=1, X
SSCPFM=USSSCS, X
USSTAB=USSMAST, X
VPACING=(0)
*
* Path definition
* xxxxxxxxxxxx is the 12 last digits of the MAC
* address of the AXIS 5470e/570/670e
*
PA5470e1 PATH DIALNO=0104xxxxxxxxxxxx, X
GID=1, X
PID=1, X
GRPNM=gggggg
*
* LU definitions. Use either LU5470e1 or LU5470e3
*
* LU type 1 (SCS)
*
LU5470e1 LU LOCADDR=2, X
DLOGMOD=SCS5470e, X
VPACING=7, X
PACING=3
*
* LU type 3 (3270DS)
*
LU5470e3 LU LOCADDR=2, X
DLOGMOD=DSC5470e, X
VPACING=7, X
PACING=3
In the PU definition, IDNUM should be set to the five last digits of the AXIS
5470e/570/670e node address,
NODE_ADDR. By default NODE_ADDR is
the five last digits of the AXIS 5470e/570/670e serial number.