User`s guide
AXIS 5470e/570/670e User’s Manual Section 4: Setting Up - AS/400
53
4. Click the Add Session button. This will start the Configuration
Wizard which is a step-by-step guide through the required IBM
configuration settings.
Verifying the
Communication Link
1. Type WRKCFGSTS *CTL xxxx* on the AS/400 command
line (xxxx is the first four characters of the AXIS
5470e/570/670e
5494 LU Name)and press Enter. After a
couple of minutes, ensure that the following items are displayed:
• One APPC controller with the same name as the AXIS
5470e/570/670e
5494 LU Name.
• One APPC device with the same name as the AXIS
5470e/570/670e
5494 LU Name, one controller session
(QRMTWSC) and the currently active printer sessions
(QRMTWSC).
• One twinax controller named
xxxxxRMT, where xxxxx are
the first five characters of the AXIS 5470e/570/670e
5494
LU Name
.
• One, two or three twinax printer devices named
xxxxPRT0z (xxxx are the first four characters of the AXIS
5470e/570/670e
5494 LU Name and z is the printer
device number).
The status of all items should now be ACTIVE or VARIED ON.
2. Type STRPRTWTR xxxxPRT0z on the AS/400 command line
(xxxxPRT0z is the printer device name) and press Enter. This
command starts the writer for this printer device.
3. Press the AXIS 5470e/570/670e test button once to print a test
page. Ensure that the SNA status is defined on the test page as
Idle, Actv or LU-4.