User`s guide

Section 4: Setting Up - AS/400 AXIS 5470e/570/670e Users Manual
48
4. Press Enter to display the SSAP list. Make sure that there is at
least one SSAP entry dedicated for SNA. For your future
reference, note the SSAP value for this entry.
Verify that the number of controllers displayed on this screen does
not exceed the value for maximum controllers (MAXCTL) from
above.
Example:
Note:
5. Press Enter to display the Autocreate controller
(AUTOCRTCTL) parameter. Ensure that the AUTOCRTCTL
parameter is set to *YES. Press F3 to return to the command line.
The SNA entry is normally set to SSAP 04.
Display Line Description S1032BB0
Linedescription.........: ETHERNET
Option..............: *SSAP
Categoryofline.........: *ELAN
----Source Service Access Points----- ----Source Service Access Points--
---
SSAP Maximum Frame Type
SSAP Maximum Frame Type
04 1496 *SNA
12 1496 *NONSNA
AA 1496 *NONSNA
C8 1496 *HPR
Bottom
Press Enter to continue.
F3=Exit F11=Display keywords F12=Cancel