User`s guide

Appendix B: SNA Gateways AXIS 5470e/570/670e Users Manual
244
The CSCON adds new parameters according to the adapter type you
have set. The resulting screen can look like this:
Example:
Example:
Concentrator
gateway, Microsoft
This is an outline of the procedure for configuring to a Microsoft SNA
Server. More information is provided in the Support section of the
Axis web site at http://www.axis.com
1. Configure host connection.
2. Configure downstream connection.
3. Select host connection and assign one or more DownStream LUs
to it.
4. Select downstream connection and associate the DownStream
LUs (from step 3) with that connection.
5. If necessary, reorder the DownStream LU numbers, that is, the
LU numbers used by the downstream system.
6. To connect multiple PUs (boxes) repeat steps 2-5.
Netware Comm Services Config V2.0 Wednesday 1999 September 4 16.27
Configure LUs for Downstream PUs _______________Downstream PU: AXIS570
DLU __Address __PU Profile __LU Address __LU Type __Model __VTAM LU Name
002 __(0x02) ____SAA_MAIN ____15 (0x0F) __Printer __________________ACP4
Netware Comm Services Config V2.0 Wednesday 1999 September 4 16.27
Configure LUs for Downstream PUs _______________Downstream PU: AXIS5470e
DLU __Address __PU Profile __LU Address __LU Type __Model __VTAM LU Name
002 __(0x02) ____SAA_MAIN ____15 (0x0F) __Printer __________________ACP4