User`s guide

AXIS 5470e/570/670e Users Manual Section 13: Using Logical Printers
221
You select your desired conversion filter by setting the Character Set
Conversion (PRx_CSET) parameter. The output from the conversion
filter is always IBM PC Set 2 (Code Page 437), and this is the
character set the printer must be set up for.
Example:
AXIS 5470e
Your network contains a host using the character set ISO 8859-2. In
order to direct its print jobs to the printer connected to the AXIS
5470e, you should assign the host to a separate logical printer, and
install a character set conversion filter.
Follow the instructions below to change the conversion filter:
1. Click admin and the Logical Printer Settings button.
2. Select the PR1 tab.
3. Set the parameter Character Set Conversion to ISO>IBM.
4. Click OK.
The ISO 8859-2 printer data that is sent to logical printer PR1 is
converted to IBM PC Set 2.
Example:
AXIS 570/670e
Your network contains a host using the character set ISO 8859-2 and
a host using the character set DEC. In order to direct their print jobs
to the same printer, e.g. LPT1, you should assign each host to a
separate logical printer, and install a character set conversion filter.
Follow the instructions below to change the conversion filter:
1. Click admin and the Logical Printer Settings button.
2. Select the PR1 tab.
3. Set the parameter Physical Port to LPT1.
4. Set the parameter Character Set Conversion to ISO>IBM.
5. Click OK.
6. Select the PR2 tab.
7. Set the parameter Physical Port to LPT1.
8. Set the parameter Character Set Conversion to DEC>IBM.