Section 21 Test Button
The test button is located on the front right hand side of the AXIS
5570e/AXIS 5670e and is used for:
Printing a test page, checking the connection to the printer.
Printing a parameter list, showing the AXIS 5570e/AXIS 5670e
current settings.
Resetting the AXIS 5570e/AXIS 5670e parameters to the factory
default settings.
The Test Page Press the test button once to print a test page. If the test page prints,
the parallel interface is functioning correctly. The printed Test Page
contains basic information about the AXIS 5570e/AXIS 5670e. It is
recommended that you print a test page every time you have
connected the AXIS 5570e/AXIS 5670e to a printer.
The Parameter List Press the test button twice to print a parameter list showing the
current AXIS 5570e/AXIS 5670e settings. This list provides
comprehensive details of all the parameters and their current status.
Refer to The Parameter List, on page 295.
If you want to change any of the parameters, use one of the methods
that are described in Management and Configuration, on page 180.
Performing a Factory
Default
Follow the instructions below to reset the AXIS 5570e/AXIS 5670e to
the factory default settings:
1. Remove the external power supply to switch off the AXIS
5570e/AXIS 5670e.
2. Press and hold down the test button, while you reconnect the
external power supply.
3. Continue to hold down the test button until the network
indicator remains constantly lit. This should take about 20
seconds.