Boeckeler Instruments, Inc. Pointmaker CPN-5600, CPN-6000 Color Video Markers - Page 49
Section ree: CPN-5600 Menu System Calibrating CPN-5600 Controllers
3. Set Verify ON or OFF.
4. Exit the menu system.
Calibrating CPN-5600 Controllers
You need to calibrate the touch screen on first installation. Calibration ensures an
intuitive and precise feel to drawing and marking over the particular moni tor you
are using.
NOTE: e calibration described in this section is the most accurate calibra-
tion for each touch screen connected to the CPN-5600. How ever, it is usually
necessary upon first power-up to do a rough calibra tion during the start-up
process. You can access this calibration through a short cut by touching the
copyright screen when it appears. e unit will activate the Touch Screen
Calibration dialog, with instructions for calibrating. is calibration is
accurate enough to operate the unit. You should then do the following
calibration proce dure to obtain the most accurate calibration.
Calibrations are automatically saved for each video port. If you move a touch
screen to a different port, run the calibration again. Or, if you have a touch screen
display with multiple video inputs, you should calibrate the touch screen for each
input.
All calibrations are stored in battery backed-up memory. e most recent cali-
bration will be recalled any time power is cycled off and on.
From the Menu System
1. Activate the menu system (see Activating the Menu, on page 29).
e Main Menu appears (see Figure 3-1: Main Menu, on page 30).
2. Select DEVICES