230 Rockwell Automation Publication MOTION-UM003F-EN-P - March 2015
Appendix A CIP Drive Module Properties
Table 36 - Module Properties: Module Info Tab Descriptions
Category Parameter Description
Identification Vendor Manufacturer of the module.
Product Type Type of module.
Product Code Usually the same as the name.
Revision Firmware revision of the module.
Serial Number Serial number of the module.
Product Name This value comes from the module. It relates to the Kinetix 6500
drive that you configured as part of your network.
Status Major Fault Unrecoverable.
Minor Fault Recoverable.
Internal State Current operational state.
Configured Displays a yes or no value that indicates whether the module is
configured by an owner controller who is connected to it.
Once you configure a module, it stays configured until you reset,
cycle power, or if the owner drops connection to the module.
Owned Displays a yes or no value that indicates whether an owner
controller is connected to the module.
Module Identity Match
For the display to Match, the following must agree:
Vendor
Module Type, the combination of Product Type and Product
Code for a particular Vendor
Major Revision
Mismatch
The values that are returned from the module do not match what
appears in the General tab.
This field does not take into account the Electronic Keying or Minor
Revision selections for the module that were specified on the
General tab.
Refresh Gathers updated data from the module.
Reset Module Resets a module to the power-up state by emulating a power cycle.
A module reset causes all connections to or through the module to be closed, and this can
result in loss of control.