Product manual

On-Site Installation Installation and Commissioning
28 Product Manual IRB 6400
2.11 Mains power connection
Before starting to connect the mains, make sure that the other end of the cable is
disconnected from the line voltage.
The power supply can be connected either inside the cabinet, or to a optional socket on
the left-hand side of the cabinet or the lower section of the front. The cable connector
is supplied but not the cable. The mains supply cables and fuses should be dimensioned
in accordance with rated power and line voltage, see rating plate on the controller.
2.11.1 Connection to the mains switch
Remove the left cover plate under the top lid. Pull the mains cable (outer diam. 10.20
mm) through the gland (see Figure 21), located on the left cabinet wall.
Figure 21 Mains connection inside the cabinet.
Connect as below (also see chapter 11, Circuit Diagram.):
1. Release the connector from the knob by pressing in the red button located on the
upper side of the connector (see Figure 21).
2. Connect phase 1 to L1 (N.B. Not dependent on phase sequence)
2 to L2
3 to L3
0 to XT26.N(line neutral is needed only for option 432)
and protective earth to
NOTE!
Max. cunductor size is 6 mm
2
(AWG 10). Tighten torque 2.3-2.5 Nm.
Retighten after approx. 1 week.
3. Snap the breaker on to the knob again and check that it is fixed properly in the right
position.
4. Tighten the cable gland.
5. Fasten the cover plate.
PE
Cable gland
Connector
XT 26