User manual

Accessory 24E2
4 E-Point Jumper Settings
Acc-24E2 Option 1 Board (Channels 3 & 4)
Jumper
Configuration
Description
Default
E1A
1-2
No Jumper for TTL Level input for CHU3 flag
Jumper 1-2 for DIR3+ output in Stepper Mode
No jumper
E1B
1-2
No Jumper for TTL Level input for CHV3 flag
Jumper 1-2 for DIR3- output in Stepper Mode
No jumper
E1C
1-2
No Jumper for TTL Level input for CHW3 flag
Jumper 1-2 for PUL3+ output in Stepper Mode
No jumper
E1D
1-2
No Jumper for TTL Level input for CHT3 flag
Jumper 1-2 for PUL3- output in Stepper Mode
No jumper
E2A
1-2
No Jumper for TTL Level input for CHU4 flag
Jumper 1-2 for DIR4+ output in Stepper Mode
No jumper
E2B
1-2
No Jumper for TTL Level input for CHV4 flag
Jumper 1-2 for DIR4- output in Stepper Mode
No jumper
E2C
1-2
No Jumper for TTL Level input for CHW4 flag
Jumper 1-2 for PUL4+ output in Stepper Mode
No jumper
E2D
1-2
No Jumper for TTL Level input for CHT4 flag
Jumper 1-2 for PUL4- output in Stepper Mode
No jumper
E7
1-2
No jumper to not tie D-shell to chassis ground
Jump 1-2 to tie J1 D-Shell to chassis ground
No Jumper
E8
1-2
No jumper to not tie D-shell to chassis ground
Jump 1-2 to ground J2 D-Shell to Chassis Ground
No Jumper
E10
1-2-3
Connects FC0 to FC3from J1 PWM AMP3 connectors to
U,V,W & T input flags on 3
rd
Channel
Jump 1-2 for high true fault signals
Jump 2-3 for low true fault signals
Jump 2-3
E11
1-2-3
Connects FC0 to FC3from J2 PWM AMP4 connectors to
U,V,W & T input flags on 4
th
Channel
Jump 1-2 for high true fault signals
Jump 2-3 for low true fault signals
Jump 2-3
E111
1-2
No jumper for direct PWM mode axis 3
Jump 1-2 for pulse and direction mode axis 3
No jumper
E112
1-2
No jumper for direct PWM mode axis 4
Jump 1-2 for pulse and direction mode axis 4
No jumper