User`s manual
20
AXIS 262+ Recording Video
Alarm recordings
Alarm recording is triggered by a signal from
an input port on the AXIS 262+, or when an
alarm notification from a network camera or
video server triggers recording..
Set a camera for alarm recording:
1. Click > Video Sources in the AXIS
262+ Web pages.
2. Select the camera to configure from the
Camera number drop-down list.
3. Set the Alarm recording radio button to
ON.
4. Select if alarms are triggered by local
input ports or by the camera.
5. Click Save.
Triggered by input port:
1.Select Alarm under Recording Options. An Alarm
Recording List appears at the top of the Alarm
recording page.
2.Select the appropriate Camera number for the
drop-down list under Alarm Recording
Configuration.
3.Select the recording Frame rate from the
drop-down list.
Click the Save button.
Triggered by camera:
1. Configure the camera/video server to send a notification message to the AXIS 262+. See
the online help of the camera or video server for instructions.
2. Select Alarm under Recording Options in AXIS 262+ Web page.
3. Select the camera to configure from the Camera number drop-down list.
4. Select the Frame rate and Max recording time under Triggered by camera.
5. Click Save.