Operating instructions

- 12 -
The unit is setup with (2) individual power inputs.
1. Accessory Power (yellow and green wire)
2. Camera Power (red and orange)
If you wish to provide a single power transformer it is recommended that:
1. Be certain that you know the total power consumption of the
housing Heaters (25 watts) + Blowers (2 watts) + camera/pan-tilt
(not supplied)
2. Check the supplied wiring chart to be sure that you have the
proper gauge wire for the distance that you intend to run your
power wires.
3. Bring power to the 3 and 4 position of the power connector (yellow
and green wire)
4. Two jumpers are provided in the housing packet. Jumper from
the 1
st
position to the 3
rd
position and from the 2
nd
position to the
4
th
position of the terminal block. Be careful not to short between
the yellow and green wires.
Add 2 jumpers
for single
power input
One Power Supply for both Camera and Accessory Power
52 watts (VA), 24 VAC, Class 2 Only
NOTE: In this combination, run power to the camera connector, then
run jumper wires (not provided) to the accessory side of the
connector.
22
90
20 18
130
16
225
14
350
12
525
10
830
Maximum distance from transformer to housing
Total vA consumed
Wire Gauge
24 VAC Wiring Distances
The following are the recommended maximum distances for 24VAC with a
10% voltage drop. (10% is generally the maximum allowable voltage drop
for AC-powered devices.)
6530
56
90 143 228 362 576
3550
POWER WIRING
Two plug-in wall transformers are included with the housing. Use
one to provide power for the heater and blower in the housing,
and the other for the camera. Determine where the transform-
ers will be located, then run two sets of power wires into the wall
mount bracket (Four total power wires). Use the chart below to
determine the correct gauge of wire needed based on the length
of the run and the 30vA power line.
CONNECTING THE TRANSFORMERS
Determine which transformer will be attached to the camera. Attach
the red and orange wires to the terminal points on the transformer
For the transformer which will be used for the heater and blower, at-
tach the yellow and green wires to the terminal points.
NOTE: You may attach wires to either terminal, however MAKE
SURE THAT THE TRANSFORMERS ARE ATTACHED TO THE
PROPER CONNECTION ON THE HOUSING.
Green
Yellow
Orange
Red
Camera
Power
Accessory
Power
Camera
Power
Accessory
Power
213 = 24 watts @ 13Vdc
214 = 14 watts @ 12Vdc
231D/232D = 25 watts @ 24Vdc
Chart A Wiring Color Code
Power and Control Inputs (Outside of housing)
For Model 25735
See camera instructions for wiring connections
CONTROL
RJ45 Ethernet Connector
Separate Power Supplies for Camera and Accessory Power
Camera: 25 watts (VA), 24 VAC, Class 2 Only
Accessory: 27 wattts (VA), 24 VAC, Class 2 Only
POWER
1 Camera Power (24 VAC) Red
2 Camera Power (24 VAC) Orange
3 Accessory Power (24 VAC) Yellow
4 Accessory Power (24 VAC) Green
ALARMS
1 Alarm 1 Blue
2 Alarm 2 Violet
3 Alarm 3 Gray
4 Common White