Instruction manual
AXIS 2400
Administration Manual Appendix A -
Troubleshooting
41
Note:
If you still have a problem after reading this information, you qualify for the “More than a minute
program” which entitles you to a free gift for a registered installation requiring more than a few
minutes. Please contact your reseller or check the FAQ should you require more assistance.
Symptoms Possible causes Remedial actions
Triggering difficulties with
programming scripts
Unable to triggering on
both positive and negative
transitions of the Control
Button and/or IO ports
(double-edged trigger-
ing).
Repetitive trigger conditions that occur in quick succession
of one another can be missed. This is because the com-
mand initiated by the first trigger event may not have been
fully executed prior to the second event. This scenario is
demonstrated in the illustration below:
This feature has particular significance when using com-
mands that take a relatively long time to process, e.g. mail
or ftp, especially if they are conjugated with a loop state-
ment. See also
Appendix H- The Programming Script
.
Bad snapshot images. Display configured incor-
rectly on your worksta-
tion.
Within Display Properties, configure your display to show at
least 65'000 colors, i.e. at least 16-bit.
Using only 16 or 256 colors on your computer will produce
dithering artifacts in the image.
Command
Command
T1
T2 T3
Command
Tr ig ge r
Time
?