User`s manual

AXIS 223M - Unit Connectors
34
Unit Connectors
This section describes the following:
The I/O terminal connector
Power connections
The RS-232 D-Sub Connector
I/O Terminal Connector
The 10-pin I/O terminal connector provides the interface to a solid state relay output, two digital photo-coupled
inputs, RS-485, GND and auxiliary power.
The terminal connector is used in applications for e.g. motion detection, event triggering, time lapse recording,
alarm notification via e-mail, image storage to FTP locations, etc.
Input - Used for connecting external alarm devices and triggering images for specific alarm-based
events. The input is typically connected to a motion detector or any other external security device, and
images can be uploaded whenever the detector is activated. Maximum 18V DC is allowed on the input.
Output - This can drive a maximum load of 50V DC at 100mA directly or heavier loads by connecting
additional relay circuitry. If the output is used with an external relay, a diode must be connected in
parallel with the load for protection against any voltage transients.
Caution!
Connecting AC to
the
inputs/outputs
will damage the
unit.
10-pin I/O terminal connector
connector
Power
block
connector
Power adapter
RS-232 connector
(including RS-485)
Connect DC power (7-24V) on pins 1 and 2
.
Connect AC power (10-24V) on pins 2 and
3
Audio out
Audio in
Reset/Control
Button
Network connector