AXIS 213 - Connection Module
Connection Module
The connection module is an optional accessory that connects to the camera and
provides the following connections:
• SERVER - for the connection to the AXIS 213 • AUDIO IN/OUT
• 2 Digital inputs • 3 Relay outputs
• VIDEO IN • VIDEO OUT
• RS-232C serial port
The connection module is configured and controlled via the camera’s user interface.
Notes: • Use an electret microphone. The microphone will be powered by the module through a 9.4k
• Use amplified speakers only, stero or mono plug
AUDIO IN/OUT
1. Connect a microphone (not supplied) to the AUDIO IN socket.
2. Connect a loudspeaker (not supplied) to the AUDIO OUT socket (amplified
speakers only).
Inputs and outputs (I/Os)
The I/Os are used in applications for, e.g. event triggering, time lapse recording, alarm
notification via email, image storage to FTP locations.
• Input - e.g. a pushbutton. If the button is pressed, the state changes, and the
input will be active (shown under Event Configuration > Port Status).
• Output - e.g. an alarm device that can be activated from Output buttons on
the Live View page, or as an action for an Event Type. If the alarm device is
activated, the output will show as active (under Event Configuration > Port
Status)
Connect to GND to activate or leave floating (unconnected) to deactivate.
Active output, electrical connection between A and B. Non active output, no connection
between A and B.
Imax=100mA, VMax=24V
I/O Description
Alarm In 1,2
Alarm GND
Alarm Out
1A,1B;2A,2B;3A,3B
Ω