User Guide
Table Of Contents
- An Introduction to the AXIS 2420
- Physical Description
- Checking The Hardware Inventory
- Installing on a Network
- Installing via a Modem
- Focusing Your Camera
- Configuring Your Camera
- The Factory Default Settings
- Choosing Your Application
- The AXIS 2191 Audio Module
- Appendix A - Troubleshooting
- Appendix B - Other IP Setup Methods
- Appendix C - Lenses and Advanced Focusing
- Appendix D - Customizing Your Camera
- Appendix E - Updating the Firmware
- Appendix F - The Unit Connectors
- Appendix G - High-Speed Services
- Appendix H - Technical Specifications
- Physische Beschreibung
- Überprüfen des Lieferumfangs
- Installieren in einem Netzwerk
- Anschließen an ein Modem
- Scharfeinstellung der Kamera
- Werkseitige Standardeinstellungen
- Description du Materiel
- Vérification de la liste du matériel
- Installation sur un réseau
- Installation par l’intermédiaire d’un modem
- Mise au point de votre caméra
- Restauration des paramètres d’usine par défaut
- Descripción física
- Comprobar el inventario de hardware
- Instalación de la cámara a una red
- Instalación de la cámara a un módem
- Enfocando la cámara
- Incluir los parámetros por defecto
- Index

The AXIS 2191 Audio Module AXIS 2420 User’s Manual
44
Troubleshooting the Audio Module
Note: If you still have a problem after reading this information, please contact your reseller, or
visit www.axis.com and check the support section for Axis camera products.
Symptoms Possible causes Remedial actions
No audio controls below
camera image.
The AXIS 2191 is not selected
as the external device.
In the camera’s administration tools, click on External Devices and
select the AXIS 2191 Audio Module.
Wrong camera firmware. Check the firmware in the camera by checking if External Devices
appears in the camera’s Administration Tools. If not, the camera does
not have the correct firmware and it must be upgraded.
No sound from the AXIS
2191 or from a PC trying to
access a web page
containing audio content.
Incorrect settings or faulty
connections.
Check that:
• soundcard, speakers and microphone are connected
• the Mute button is not pressed
• the Int/Ext switch for the input is in the correct position
• the input and output levels are correct
• all cabling is connected and all power switches are ON
No audio signal from PC to
the AXIS 2191 when passing
a proxy server.
The Post Content Length set
in the proxy server is too low.
Set the value of the Post Content Length in your proxy server to 1MB
or more. You may need to contact your system administrator to do
this.
No full-duplex function. Incorrect configuration. Check the setting in the camera’s administration tools.
Sound card does not support
full-duplex.
For information on how to check if your sound card supports
full-duplex, please visit www.axis.com and see the support section for
Axis camera products.
Poor performance. Too many users/clients
connected.
Try limiting the number of clients allowed to connect.
Low bandwidth. Reduce the available bandwidth by changing to a lower setting in the
Available Bandwidth selector. Setting a lower bandwidth will reduce
any break-up in the sound, but will also increase the transmission
delay.
If running in Full-Duplex mode, try switching to Half-Duplex mode.
Whining or screeching sound
from speakers (feedback).
Poor positioning of speakers
and/or microphone.
Relocate the speakers or microphone so that they do not point
towards each other, and/or lower the volume.
Poor sound on headphones. Incorrect connection. Headphones can only be used by connecting them to Speaker-Out on
the terminal connector.
The Power indicator LED is
not constantly lit.
Faulty power supply. Verify that you are using an AXIS PS-D power supply.
The AXIS 2191 works locally,
but not externally.
Firewall protection. Check the Internet firewall with your system administrator.
Default routers required. Check if you need to configure the default router settings.