User Manual

AXIS P3384–V
System Options
If the card’s status shows as failed, click Check disk to see if the problem can be found and then try Repair. This option is only
available for SD cards with ext4. For SD cards with vFAT, use a card reader or computer to troubleshoot the card.
To avoid lling the card, it is recommended to remove recordings continuously. Under Recording Settings, select Remove recordings
older than and select the number of days or w eeks.
To stop writing to the card and protect recording s from being removed, select Lock under Recording Settings.
Network Share
Network share allows you to add network storage such as a N AS (Network Attached Storage) or any server that uses CIFS (Common
Internet File System) a nd use them for storage of recordings.
To add a network share:
1. Go to System Options > Storage.
2. Click Network Share.
3. Enter the IP address, DNS or Bonjour name to the host server in the Host eld.
4. Enter the name of the share in the Share eld.
5. If required, select The share requires login and enter the user name and password.
6. Click Connect.
To clear all recor dings and data from the Axis product’s folder on the designated share, click Clear under Storage Tools.
To avoid lling the share, it is recommended to remove recordings continuously. Under Recording Settings,selectRemov
e recordings
older than and select the number of days or w eeks.
To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.
Ports & Devices
I/O Ports
The Axis product provides one input port and one output port for connection of external devices. For information on h ow to
connect external devices, see Connectors on pag e 4 .
The I/O p orts are congured under System Options > Ports & Devices > I/O Ports. The ports can be given descriptive names and their
Normal states can be con
gured as Open circuit or Grounded circuit.
Port Status
The list on the System Options > Ports & Devices > Port Status page shows the status of the product’s input and output ports.
Mai
ntenance
The Axis product provides several maintenance functions. These are available under System Options > Maintenance.
Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current
settings.
Click Restore to reset m ost settings to the factory default values. The following settings are not affected:
the boot pro tocol (DHCP or static)
the static IP address
46