Appendix B: The Parameter List AXIS 240 Users Manual
78
Factory Default Settings
If you should need to reset the AXIS 240 to its factory default settings,
you can use the Control button. Follow these steps:
1. Switch off the AXIS 240 by unplugging the power cord.
2. Press and hold the Control button while you switch on the AXIS
240. Keep the Control button pressed until the Active indicator
flashes at regular two second intervals.
3. Release the Control button and wait at least two seconds (one
flash of the Active indicator).
4. Press and hold the Control button for at least five seconds until
the Active indicator remains constantly lit.
5. If you need to restore the default IP address, press and hold the
Control button once again until the Active indicator starts
flashing. Otherwise, the IP address setting will remain unchanged.
6. The AXIS 240 is now reset to factory default settings. Restart the
AXIS 240 by switching it off and on.
Note:
❏ The node address ( NODE_ADDR parameter) remains
unchanged, but all other parameters are reset.