User Manual

Table Of Contents
Configuring the AXIS 240 AXIS 240 Users Manual
32
Date & Time Page
You can specify the current date and time via the Configuration - Date
& Time page. Click Date & Time at the top of the Configuration
page.
The following is a description of the Date & Time parameters
:
Parameter name Description
Date The current date.
Time The current time. The time must be specified in 24 hour
format, e.g. 5 pm should be entered as 17 in the hour
field.
Datesync Server
Datesync Period
Datesync Protocol
Datesync Time Zone
To activate the integrated date and time synchronization
mechanism, you must provide the IP address of a date
server, a synchronization period (in minutes) bigger than
zero, the synchronization protocol and time zone
adjustment. The date server provides the actual time and
date when connected at TCP port 13 (Daytime protocol),
TCP port 37 (Time protocol) or UDP port 123 (NTP
protocol), respectively. The date and time will be
automatically updated in intervals as specified by the
synchronization period. Default values are 0.0.0.0, 0,
Time and 0, respectively.
Display Date/Time When set to yes, a date and time stamp will be
superimposed upon the snapshot image, displayed in the
format Hour:Minute:Second Day-Month-Year.
Time format Presents time in either of these formats: 24 hours or
AM/PM.
Clock Position x
Clock Position y
These settings determine where the date and time stamp
will be placed within the snapshot. The stamp will always
appear within the snapshot area, regardless of whether
one or more of the co-ordinates are out of limit. If they
are, the stamp will be displayed as close as possible to
the furthest co-ordinate within the snapshot boundary.