System information

Manual:System/UPS
59
Property Description
alarm-setting (delayed | immediate |
low-battery | none; Default: immediate)
UPS sound alarm setting:
delayed - alarm is delayed to the on-battery event
immediate - alarm immediately after the on-battery event
low-battery - alarm only when the battery is low
none - do not alarm
min-runtime (time; Default: 5m) Minimal run time remaining. After a 'utility' failure, the router will monitor the runtime-left value.
When the value reaches the min-runtime value, the router will go to hibernate mode.
0 - the router will go to hibernate mode when the "battery low" signal is sent indicating that the
battery power is below 10%
offline-time (time; Default: 5m) How long to work on batteries. The router waits that amount of time and then goes into hibernate
mode until the UPS reports that the 'utility' power is back
0 - the router will go into hibernate mode according the min-runtime setting and 10% of battery
power event. In this case, the router will wait until the UPS reports that the battery power is
below 10%
port (string; Default: ) Communication port of the router.
Read-only properties:
Property Description
load (percent) The UPS's output load as a percentage of full rated load in Watts. The typical accuracy of this
measurement is ±3% of the maximum of 105%
manufacture-date (string) UPS's date of manufacture in the format "mm/dd/yy" (month, day, year).
model (string) Less than 32 ASCII character string consisting of the UPS model name (the words on the front of the UPS
itself)
nominal-battery-voltage
(integer)
UPS's nominal battery voltage rating (this is not the UPS's actual battery voltage)
offline-after (time) When will the router go offline
serial (string) A string of at least 8 characters directly representing the UPS's serial number as set at the factory. Newer
SmartUPS models have 12-character serial numbers
version (string) UPS version, consists of three fields: SKU number, firmware revision, country code. The county code
may be one of the following:
I - 220/230/240 Vac
D - 115/120 Vac
A - 100 Vac
M - 208 Vac
J - 200 Vac
Note: In order to enable UPS monitor, the serial port should be available.
Example
To enable the UPS monitor for port serial1:
[admin@MikroTik] system ups> add port=serial1 disabled=no
[admin@MikroTik] system ups> print
Flags: X - disabled, I - invalid
0 name="ups" port=serial1 offline-time=5m min-runtime=5m
alarm-setting=immediate model="SMART-UPS 1000" version="60.11.I"