User Manual

Gateway - QSG
Power
AC Mains Power
The Gateway typically operates from
mains power, either 110-120V AC or
220-240V AC 50Hz or 60Hz. The
voltage selection (120 or 240vac) is a
factory option and is indicated on the
main board.
An outdoor-rated (UV stabilized) AC
cable connects power to the gateway
through a waterproof cable gland. The
AC cable must be connected to a
grounded outlet.
WARNING: failure to connect or
bypassing the chassis
ground can result in
extremely dangerous
conditions. Observe all local
electrical code requirements; consult
with a licensed electrician if in doubt.
The AC cable connects to screw
terminals on the main board beneath
the black aluminum safety shield. The
AC ground wire connects to the
chassis ground.
The AC safety shield helps prevent
accidental access to AC mains
voltages. The AC cable is field
replaceable, but cable replacement
should only be performed by qualified
personnel and only with AC power off
and disconnected.
The safety shield mounts to the main board with 4 locking feet and is secured with a single
machine screw through the Saftey Shield Lock. This screw also grounds the safety shield; a
stainless-steel screw and lock washer must be used to ensure proper grounding of the safety
shield. The safety shield should not be removed while AC power is connected to the Gateway.
Note that the AC shield also serves as the AC heater and may be hot.
To remove the AC cable:
1. Loosen the safety shield lock screw but do not remove it.
2. Grasp the AC safety shield on both sides and slide it towards the top of the chassis
3. Lift the AC safety shield straight up so the locking feet clear the slots in the main board
4. Disconnect the heater connector if present
5. Remove the AC safety shield and heater assembly from the chassis.
6. Loosen the AC screw terminal connections
7. Loosen the AC cable gland
8. Remove the AC cable
Copyright 2011, Axiometric, LLC Page 8 Confidential