Read Tasks
MIU reads are typically performed in response to an
assigned workorder (task). MIUs may also be
independently read by a technician to collect the latest
register reading. The read process is very similar for
assigned and independent reads: Press “Read” on the
Home page for an independent Read. When prompted,
activate the MIU to be read by placing a magnet on the
activation location on the MIU. When the MIU has been
successfully activated, it will initiate radio communication
with the SMiRF and in a few seconds the SMiRF will beep
to indicate that the MIU has been detected; it will then
gather reading and status information from the MIU using radio communications and
display it on a screen for review:
• Meter - Meter Id
• MIU – MIU serial number
• Reading - The last register reading recorded by
the MIU. Pulse registers always return the
current reading as shown on the face of the
register. Encoded registers are read hourly and
the reading returned will be accurate within the
last hour.
• Firmware - The current MIU firmware version
• Battery - the MIU battery voltage
• Alerts - any alerts (problems) on the MIU
It is critical to confirm that this information is correct, especially the MIU and Meter ID.
When many technicians are working in the same area, it is possible that the SMiRF
received a message from a different MIU that was activated by another technician. It is
very important to check the Meter Id and MIU ID to ensure the reading is properly
recorded.
When done viewing the reading information, tap “OK”. If completing a task, you will
return to the workorder/task display. If completing an independent read, you will return to
the activate MIU screen ready to perform another reading.