User's Manual
Axiometric Gateway Guide MeshPlus™
(wait for "OK")
-- Force attachment as class 'CG'
[The default is a 'class B' device.]
(GPRS-only - no voice service, no GSM service, auto-activate the IP stack,
and auto-attach on power-up)
type: AT+CGCLASS="CG"
-- set DLE mode ON for connection ID 1
type: AT#DLEMODE=1,1
-- set TCP PORT for listen:
type: AT#TCPPORT=1,2100
-- set TCP SERVER to allow incoming call from any host:
type: AT#TCPSERV=1,"255.255.255.255"
-- set DLE mode ON for connection ID 2
type: AT#DLEMODE=2,1
-- set TCP PORT for listen:
type: AT#TCPPORT=2,2100
-- set TCP SERVER to allow incoming call from any host:
OPTION:
NORMAL: type: AT#TCPSERV=2,"255.255.255.255"
OR, TO ENABLE BACKUP COLLECTOR: type: AT#TCPSERV=2,"64.32.161.115"
-- set your APN, username, and password (wait for "OK" after each one)
**** NOTE: double-and-triple check the username and password; Cingular
mixes up ones and 'I's and 'L's and zeroes and 'o's in their passwords.
**** NOTE: the quotes around strings, (e.g.username/password/apnserv are required)
type: AT#APNSERV="your APN [e.g. wwan.ccs]"
type: AT#APNUN="your username"
type: AT#APNPW="your password"
Once all the other configuration is done, turn off local echo and save
that state to EEPROM:
-- type: ate0
(wait for "ok")
-- type: at&w
(wait for "ok")
Configuration is complete. Confirm connectivity with the Gateway2 prior to
installation.
d) POTS Modem Network Bridge
The POTS modem bridge function is not supported in the current firmware
4. Redundant Configurations
Multiple Gateway 2s may be deployed in a mesh for redundancy. If a primary Gateway 2 is