User's Guide

PE_QW1_V04_US
9
It is recommended to select meter installation place as far as possible from potential sources of
vibration (for example, pumps).
The gaskets must match with the pipe diameter. During the installation gasket must be exactly centered
with the center of the pipe cross-section to avoid sticking out gaskets inside the pipe.
Checking of installation and parameter setting
If the meter is installed correctly, when there is flow, the display of the meter should display flow readings.
It is necessary to check whether the meter is installed in the correct direction, whether there is no air in the
system.
6 OPERATION
Display functions
The water meter is equipped with 2- lines LCD (Liquid Crystal Display): Upper line - 9-digits for
displaying measured volume of water; Lower line - 5-digits for displaying current flow rate and special symbols
for displaying operation modes
ftm/h
3
ftm
3
Flow arrows:
- flow is flowing forward
- flow is flowing backwards*
arrow is not displayed - flow does not flow
Remark: * for reverse flow, the meter shows backflow GAL and an error code is also
sent, due to backflow. The direct water volume summation record remains unchanged.