Install Instructions for MF200
2615 Wentz Avenue, Saskatoon, SK S7K 5J1 Ph: (306) 651-1815 Fax: (306) 651-2293
email: sales@axiomind.com website: www.axiomind.com
Pressure
switch
Pump
Float switch
DC jack from
Power Supply
MF200 Installation Instructions for the RIA10-1-SAA Control Panel
The low level float switch in the MF series is factory wired to be OPEN on LOW LEVEL. Remove the
screws fastening the top cover to the unit and lift the cover to get access to the float switch wiring.
Disconnect the power before doing this.
Cut wires here
Step 1:
Cut
wires connecting float switch to MF200
circuit.
Step 3:
Complete MF200 circuit without float
switch.
Step 2:
Remove Float switch from MF200 circuit.
Step 4:
Extend the wires from the float switch and push
the float cable through strain relief fitting in control panel
and connect float wires to terminals 1 and 2 on terminal
strip. Tighten strain relief nut to secure cable into panel.