Install Instructions
Connections to the appliance and neutralization kit must be installed to ensure that no condensate backflow
can occur. Connect corrosion resistant piping and secure it to the floor or wall to prevent movement. Do not
route the condensate line through any area that is exposed to freezing temperatures. If traffic poses a risk,
install some protection to prevent movement and/or damage. Install a Y or T-fitting as a safety overflow in
the event that the condensate drain becomes clogged. Mount as per installation diagram. Any connection
supplied with the NC unit should be installed after the trap. Ensure that the condensate will flow freely from
the appliance drain into the capsule then to the drain. Access to the discharge is necessary for proper
maintenance in order to check the effectiveness of the neutralizing media, using pH test strips.
If there is no gravity drain available, install a condensate removal pump designed for use on condensing
boilers and furnaces. The condensate pump must be equipped with an over flow switch to prevent the
appliance from running should a failure occur.
Operation
The appliance condensate will flow through the neutralizing media, raising the pH of the condensate
to a level that will help prevent corrosion of the domestic drain and the public sewer system.
Maintenance
Monitor the cleanliness, level of the neutralization media, and pH level in the capsule monthly. Remove any
debris found to prevent blockages and check the pH level at the outlet of the neutralizing kit using a suitable
pH test strip paper or an electronic pH meter for precise measurement. The neutralizing media should be
replaced when the pH level drops below the minimum level of the local water authority, or after one year,
whichever comes first. For replacement media contact your local Axiom distributor.
Limited Warranty
The unit is warranted against defects in materials and workmanship for one year.