Safety Data Sheet
Page 3/7 
(Contd. on page 3) 
41.1.5
CA 
Safety Data Sheet 
acc. to OSHA HCS 
Printing date 08/07/2015  Reviewed on 05/07/2018
Trade name: AXI-THERM CLEAN 5 
9 Physical and chemical properties 
· 
Information on basic physical and chemical properties 
· 
General Information 
· 
Appearance: 
                         Form: 
Fluid 
                         Color: 
Ocher 
· 
Appearance:     
Characteristic
pH-value at 20 °C: 
6.7 
Change in condition 
Melting point/Melting range: 
Undetermined. 
Boiling point/Boiling range: 
100 °C 
Flash point: 
Not applicable. 
Flammability (solid, gaseous):   
Not applicable. 
Auto igniting:    
Product is not selfigniting. 
(Contd. of page 2) 
· 
Information about protection against explosions and fires: 
No special measures required. 
· 
Conditions for safe storage, including any incompatibilities 
· 
Storage: 
· 
Requirements to be met by storerooms and receptacles: 
Store in a cool location. 
Store only in the original receptacle. 
· 
Information about storage in one common storage facility: 
Not required. 
· 
Further information about storage conditions: 
Keep receptacle tightly sealed. 
· 
Storage class: 
12 
· 
Specific end use(s) 
No further relevant information available. 
8 Exposure controls/personal protection 
· 
Additional information about design of technical systems: 
No further data; see item 7. 
· 
Control parameters
· 
Components with limit values that require monitoring at the workplace: 
57-55-6propane-1,2-diol 
EV 
Long-term value: 155* 10** mg/m
3
, 50* ppm 
*vapour and aerosol;**aerosol only 
· 
Additional information: 
The lists that were valid during the creation were used as basis. 
· 
Exposure controls
· 
Personal protective equipment:
· 
General protective and hygienic measures:
The usual precautionary measures for handling chemicals should be followed.
· 
Breathing equipment: 
Not required. 
· 
Protection of hands: 
Protective gloves 
· 
Material of gloves 
Neoprene gloves 
· 
Penetration time of glove material
The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be 
observed.
· 
Eye protection: 
Goggles recommended during refilling. 