User manual
APOS Premium Printer Series User Manual Page 96 /136 Reference: FDE 3107312 Issue A
R
EAL TIME PRINTER STATUS TRANSMISSION
Transmits one byte status of the printer in real time.
ASCII
GS ENQ
Hexadecimal 1D 05
Decimal
29 5
Value of Byte
Bit Status Hex Decimal Function
0 Off 00 0 Undefined
1 Off 00 0 Undefined
2 Off
On
00
04
0
4
Cover closed.
Cover open.
3 Off
On
00
08
0
8
Not busy at the communication interface.
Printer is busy at the communication interface.
4 Off
On
00
10
0
16
CDKO Open.
CDKO Close.
5 Off 00 0 Fixed to Off.
6 Off
On
00
40
0
64
No error condition.
Error condition exists in the printer.
7 On 80 128 Fixed to On.