User manual
APOS Premium Printer Series User Manual Page 65 /136 Reference: FDE 3107312 Issue A
D
EFINE USER-DEFINED CHARACTER SET WITH VARIABLE HEIGHT
Command format is similar to existing command 1B 26. The only difference resides in the height encoding
H indicates the height in number of dots instead of number of byte (1B 26) to provide better resolution.
Data are still encoded vertically.
max dimensions : Hmax = 64, Wmax = 48
ASCII
US & H cn cm ln [dn1…dnk] lm [dm1…dmk]
Hexadecimal 1F 26 H cn cm ln [dn1…dnk] lm [dm1…dmk
Decimal
31 38 H cn cm ln [dn1…dnk] lm [dm1…dmk]
Values and Ranges
Parameter H indicates character height in number of dots, and does not have to be dividable by 8.
From 1 to 8 dots high => 1 data byte per column
From 9 to 16 dots high => 2 data bytes per column
From 17 to 24 dots high => 3 data bytes per column
Etc…
Top of Character
dn
MSB
LSB
d1
d2
d3
d4
d5
dn
A
CTIVE USER-DEFINED FONT SELECTION
ASCII
US i n
Hexadecimal 1F 69 n
Decimal
31 105 n
n = 0, 1, 2, 3
default = 0
Selects the active user defined font used by commands 1B 26, 1F 26, 1B 25, 1B 3A, 1B 3F.
Setting remains unchanged until printer reboots, or command 1B 40 resets active user defined font to
default.