User manual
APOS Premium Printer Series User Manual Page 99 /136 Reference: FDE 3107312 Issue A
Second Variation Length of Byte Specified at Beginning of String
The value of m selects the bar code system as described in the table.
The variable d indicates the character code to be encoded into the specified bar code system. See the table.
If character code d cannot be encoded, the printer prints the bar code data processed so far, and the
following data is treated as normal data.
m Bar Code D n, Length
65 UPC-A 48- 57 (ASCII numerals) Fixed Length: 11,
12
66 UPC-E 48- 57 Fixed Length: 11,
12
67 JAN13 (EAN) 48- 57 Fixed Length: 12,
13
68 JAN8 (EAN) 48- 57 Fixed Length: 7, 8
69 CODE39 48- 57,
65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII special characters)
d1 = dk = 42 (start/stop code is supplied by printer if
necessary)
Variable
70 Interleaved 2
of 5 (ITF)
48- 57 Variable (Even
Number)
71 CODABAR
(NW-7)
65- 68, start code
48- 57,
36, 43, 45, 46, 47, 58
Variable
72 Code 93 0-127 Variable
73 Code 128 0-105
d1 = 103-105 (must be a Start code)
d2 = 0-102 (data bytes)
(Stop code is provided by the printer)
Variable
75 PDF 417 0-255 Variable Length
S
ELECT BAR CODE WIDTH
Sets the bar code module to n/203 inch (n/8 mm).
ASCII
GS w n
Hexadecimal 1D 77 n
Decimal
29 119 n
Value of n
2, 3, 4, 5,6
Default
n=3
Formulas
n/203 inch (n/8 mm)