Real time status transmission
GS sequence DLE sequence
ASCII GS EOT n DLE EOT n
Hexadecimal 1D 04 n 10 04 n
Decimal 29 4 n 16 4 n
Value of n:
GS/DLE sequence
1 = Transmit printer status
2 = Transmit RS-232C busy status
3 = Transmit error status
4 = Transmit receipt paper status
Transmits the selected one byte printer status specified by
n in real time according to the following parameters. This
command includes two sequences: GS (1D) and DLE
(0x10).
Exceptions
The command is ignored if n is out of range.
An application using DLE (0x10) sequence must send
EOT within 100 milliseconds of DLE or the printer will
misinterpret the DLE and execute a clear printer
command. Avoid this possibility by using the ID 04 n
sequence, which is handled exactly the same as 10 04 n.
Unlike the A793, that had a dedicated connector and
resultant dedicated status reporting for each cash drawer,
the A795 has a single connector that shares data reporting
from either cash drawer. When either cash drawer is open,
an open status is reported by the printer.
Related information
1 = Transmit printer status
Bit Status Hex Decimal Function
0 Off 00 0 Fixed to Off.
1 On 02 2 Fixed to On.
2 Off 00 0 One or both cash
drawers open.
On 04 4 Both cash drawers closed.
3 Off 00 0 Not busy at the
RS-232C interface.
On 08 8 Printer is busy at the
RS-232C interface.
4 On 10 16 Fixed to on.
5 Undefined.
6 Undefined.
7 Off 00 0 Fixed to off.
2 = Transmit RS-232C Busy Status
Bit Status Hex Decimal Function
0 Off 00 0 Fixed to off.
1 On 02 2 Fixed to on.
2 Off 00 0 Cover closed.
On 04 4 Cover open.
3 Off 00 0 Paper feed button
is not pressed.
On 08 8 Paper feed button is pressed.
4 On 10 16 Fixed to on.
5 Off 00 0 Printing not stopped due
to paper condition.
On 20 32 Printing stopped due to
paper condition.
6 Off 00 0 No error condition.
On 40 64 Error condition exists in
the printer.
7 Off 00 0 Fixed to off.
Real time status transmission (continued)