Setup guide

*** A795 – Diagnostics Form ***
Model number : A795-2119
Serial number : A012251287
Boot Firmware
Revision : V1.02
CRC : 76EB
P/N : 189-1076076A
Flash Firmware
Revision : V1.13
CRC : AB62
P/N : 189-7950290A
H/W parameters
Flash Memoriy Size : 2 Mbytes
Flash Logos/Fonts : 1024 kbytes
Flash User Storage : 0 kbytes
SRAM Size : 256 kbytes
Head setting : D
Paper Type setting : Type 5, Version 0
Color Density Adj : 100%
Print Density (Mono) : 100%
Max Speed : 100 mm/sec
Paper Width : 80 mm
Max Power : 55 W
Knife : Enabled
Partial Cut : 135 steps
Paper Low Sensor : Disabled
Comm. Interface
RX Buffer Size : 4096
Interface type : RS232/USB
Parameters
Baud Rate : 115200
Data Bits : 8
Stop Bit : 1
Parity : NONE
Flow Control : DTR/DSR
Reception Errors : Ignore
Alternate DTR/DSR : Disabled
USB Driver Type : RS232 Emulation
Resident Code Pages : 437, 850, 852, 858
860, 863, 865, 866
1252, 862, 737
Available Paper Types : 00.00 01.00 05.00
01.90 01.92 01.93
Logo(s) defined : Yes
User Char(s) defined : NO
To enter Printer Config Menu :
1) Flip DIP switch #1 down
2) Reset the printer, while holding
the Paper Feed button down
**************************************
**************************************
Select a sub-menu :
EXIT
-
> 1 click
Print Current Configuration
-
> 2 clicks
Set Communication Interface
-
> 3 clicks
Set Diagnostics Modes
-
> 4 clicks
– Set Emulation/Software Options
-
> 5 clicks
– Set Hardware Options
-
> 6 clicks
– Set Paper Type
-
> 7 clicks
Enter code, then hold Button DOWN
at least 1 second to validate
MAIN MENU
5
Run a diagnostic test to test the printer (page 23).
6
Configure the printer if necessary (page 25 in User Guide and Programming
Supplement for command descriptions and usage).
Print Test and Configuration Menu Sample. Samples will vary depending on the printer model.
The A795 is LogoEZ® compatible for ease of setting-up your logo and two-color design needs.
The paper type can be changed
in the configuration menu.
Paper types and grades available:
Type 0 - Monochrome grades
Kanzaki P-310
Type 1 - Two-color grades
Kanzaki P-310 RB (red/black)
Type 4 - Two-color grades
Kanzaki P-320 BB (blue/black)
Type 5 - Two-color grades
Kanzaki P-320 RB (red/black)
See User and Programming guides for more
information.
When the printer is configured for USB and the
native USB solution driver is used, this location will
show either: “USB Driver Type: TPG, Inc.” or “USB
Driver Type: Printer Class”. If the RS-232C, USB
emulation solution driver is used, nothing is
printed here. See User Guide, Appendix A.
Open
Cover
Push and hold
Paper Feed Button
while closing Cover