Instruction manual
A794 Owner’s Guide Chapter 6: Programming Information
December 1999 65
Select Sensors to Stop Printing
ASCII ESC c 4 n
Hexadecimal 1B 63 34 n
Decimal 27 99 52 n
Value of n: Sensor status
Sensor Status
Bit Sensor 0 1
0 Receipt Paper Near-End Disabled Enabled
1 Receipt Paper Near-End Disabled Enabled
2-4 Undefined
6 Undefined
Bits 5 and 7 are not used.
Default: 0
Determines which sensor stops printing on the respective station. The command does
not affect the paper out status on the receipt station, which will automatically stop the
printer when the paper is depleted.
Enable or Disable Panel Button
ASCII ESC c 5 n
Hexadecimal 1B 63 35 n
Decimal 27 99 53 n
Value of n: 0 = Enable
1 = Disable
Default: 0 (Enable)
Enables or disables the Paper Feed Button. If the last bit is 0, the Paper Feed Button is
enabled. If the last bit is 1, the Paper Feed Button is disabled.
Exceptions
Functions that require the Paper Feed Button (except for the Execute Macro [1D 5E]
command) cannot be used when it has been disabled with this command.