Setup guide

16
Check that the printer is powered. A green light, located on the top of the
printer should be ON.
Verify that the printer configuration settings are as outlined in the “Setup of
the Axiohm printer” section above.
Check that the Axiohm cable or compatible RS232 null modem cable is
connected between the printer and the 10K120 interface.
Check that the 10K120 interface is securely plugged into one of the mating
ports on the back of the 2127 register. It should be latched into the receptacle
connector.
What if the printer line spacing, knife cut, or other print formatting is off?
Verify the Machine Definition Codes and Program 18 settings are as outlined
in the sections above.
There are many settings in the 2127 register that can affect receipt
appearance and print positioning and can be tailored to individual
preferences. See the three 2127 manuals mentioned above for more
detail on the possible customization that can be performed to alter
the appearance of the receipt.
What if MICR does not operate?
Check that the 10K96 cable is connected to the 10K120 interface and is in the
correct port on the 2127register. Try the other RS232 port on the 2127 OCRS
board if the first is nonfunctional.
Check the 10K120 MICR reader setting to verify that it is enabled and the
Dumac Format setting is properly set for your system configuration.
Contact Dumac at 315-463-1010 if you have questions concerning MICR
settings on the 2127 register.
What if the EJ function appears not to operate?
If using an Axiohm A760 printer to store EJ data, verify that the printer has
the firmware version, as shown on the A760 Diagnostic Form above, or
newer.
Check that the 10K120 EJ Data Storage setting is enabled and that the desired
access method for printing and erasing the EJ data is enabled.