Instruction manual
A758 Owner’s Guide Chapter 7: Programming Guide
September 1999 177
Second Variation: Length of Byte Specified at Beginning of String
m
= 65 - 73, 75 (see the table)
d
= 0 - 127 (see the table)
n
= 1 - 255 (see the table)
The value of
m
selects the bar code system as described in the table. When data is
present in the print buffer, the printer processes the data following
m
as normal
data.
The variable
d
indicates the character code to be encoded into the specified bar
code system. See the table. If character code
d
cannot be encoded, the printer
prints the bar code data processed so far, and the following data is treated as
normal data.
m Bar Code d n, Length
65 UPC-A 48- 57 (ASCII numerals) Fixed Length: 11, 12
66 UPC-E 48- 57 Fixed Length: 11, 12
67 JAN13 (EAN) 48- 57 Fixed Length: 12, 13
68 JAN8 (EAN) 48- 57 Fixed Length: 7, 8
69 CODE 39 48- 57, 65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII
special characters)
d1
=
dn
= 42 (start/stop code is
supplied by printer if necessary)
Variable
70 Interleaved 2
of 5 (ITF)
48- 57 Variable
(Even Number)
71 CODABAR
(NW-7)
65- 68, start code
48- 57, 36, 43, 45, 46, 47, 58
Variable
72 Code 93 48- 57, 65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII
special characters)
d1
=
d
n = 42 (start/stop code is
supplied by printer if necessary)
Variable
(A758 Native Mode
only)
73 Code 128 0-105
d1
= 103-105 (must be a Start code)
d2
= 0-102 (data bytes) (Stop code is
provided by the printer)
Variable
75 PDF417 0 – 255 Variable Length
(A758 Native Mode
only)
Exceptions:
Illegal data cancels this command.
The command is valid only at the beginning of a line.
PDF 417 format cannot be printed on the slip.
Barcodes on the Slip are always right justified.
PDF417 and Code 93 are only available in A758 Native Mode.