Instruction manual
A758 Owner’s Guide Chapter 7: Programming Guide
September 1999 162
Cash Drawer Status (
n
= 2 or
n
= 50)
Bit Off/
On
Hex Decimal Status for Transmit Status
0Off
On
00
01
0
1
One or both cash drawers open.
Both cash drawers closed.
1Off
On
00
02
0
2
One or both cash drawers open.
Both cash drawers closed.
2- - - Undefined
3- - - Undefined
4 Off 00 0 Not used. Fixed to off.
5- - - Undefined
6- - - Undefined
7 Off 00 0 Not used. Fixed to off.
Slip Paper Status (
n
= 3 or
n
= 51)
Value of Byte Returned Slip Status
0 There is no more printing space on the current slip, or the
slip paper is not selected.
1 to 8 Remaining print area on the current slip, in number of
lines, at the currently set line spacing, when the trailing
edge sensor has become uncovered.
Until the trailing edge sensor becomes uncovered the
value reported will be 6, because there are at least 6 lines
remaining.
There can be 7 or 8 lines remaining when the slip line
spacing has been set to less than 7.2 lines per inch.
Flash Memory Status (
n
= 4 or
n
= 52)
Bit Off/On Hex Decimal Status for Transmit Status
0 Off 00 0 Undefined. Fixed to off.
1 Off 00 0 Undefined. Fixed to off.
2Off
On
00
04
0
4
User data storage write successful.
User data storage write failed. Specified area not
erased.
3Off
On
00
08
0
8
Flash logo area adequate. Definition stored.
Flash logo area not adequate for recent definition.
4 Off 00 0 Not used. Fixed to off.
5Off
On
00
20
0
32
No thermal user-defined characters written to
Flash
Thermal user-defined characters written to Flash.
6Off
On
00
04
0
64
No impact user-defined characters written to Flash.
Impact user-defined characters written to Flash.
7 Off 00 0 Not used. Fixed to off.
Range of
n
:
1 – 4
49 - 52
Exceptions:
When
n
is out of the specified range, the command is ignored.