Instruction manual

A758 Owner’s Guide Chapter 7: Programming Guide
September 1999 160
Value of
n
Remote Diagnostic Item Function
ASC Hex Dec
Ñ A5 165 Flash cycles tally Write to NVRAM, and print on receipt to verify
a
A6 166 Flash cycles tally Clear Flash cycles cut tally to 0
o
A7 167 Flash cycles tally Return Flash cycles cut tally, returns 10 bytes
¿
A8 168 Knife jams tally,
8 digit ASCII
numeric,
max 99,999,999
Write to NVRAM
A9 169 Knife jams tally Write to NVRAM, and print on receipt to verify
AA 170 Knife jams tally Clear Knife jams tally to 0
½
AB 171 Knife jams tally Return Knife jams tally, returns 10 bytes
¼
AC 172 Cover openings
tally, 8 digit ASCII
numeric,
max 99,999,999
Write to NVRAM
¡
AD 173 Cover openings
tally
Write to NVRAM, and print on receipt to verify
«
AE 174 Cover openings
tally
Clear Cover openings tally to 0
»
AF 175 Cover openings
tally
Return Cover openings tally, returns 10 bytes
B2 178 Max Temperature
tally
Set Max temp tally to -273
|
B3 179 Max Temperature
tally
Return Max Temperature tally, returns 10 bytes
B4 180 Slip lines tally,
8 digit ASCII
numeric,
max 99,999,999
Write to NVRAM
B5 181 Slip lines tally Write to NVRAM, and print on receipt to verify
B6 182 Slip lines tally Clear Slip lines tally to 0
B7 183 Slip lines tally Return Slip Lines tally, returns 10 bytes