ITEM COMMENTS
Vibration:
Sinusoïdal vibration tests
The standard used for this test was : IEC68-2-6
5-9 Hz, 6 mm displacement
9-200 Hz, 1g of accélération.
1 octave / minute
12 cycles per axis
3 axes
Printer unpacked and operating
Random vibration tests
The standard used for this test was : IEC 68-2-36
5-200 Hz, DSP : 0.01 g2/Hz
200-500 Hz, DSP : 0.003 g2/Hz.
mean acceleration : 1.7 g
Duration : 30min per axis
3 axes
Printer unpacked and operating
Shake vibration tests
The standard used for this test was : IEC 68-2-29
Wave : half sinusoidal
Acceleration : 15 g
Duration : 6 ms / 500 buffets
6 axes (±OX, ±OY, ±OZ)