User manual

A630/A631/A632 Printer Series User Manual Page 20 / 63 Reference: FDE 3106894 Issue F
3.1.6.3 Charging the battery (A631)
When the battery is low, the green led flashes slowly. The printer stops when the battery is empty.
The charge begins when the printer is connected to the power supply: the green led flashes rapidly. When
fully charged, it stops automatically (charging time is about 1h 30 min).
Recommendation:
Never try to re-charge a full battery, you could damage it.
The charge cannot start if the cover is open or if there is no paper in the printer (red led
flashing).
When not using the printer for more than 24 h, unclip the battery from the printer. This will
prevent the battery from discharging.
Printing while charging the battery is possible, but the charge stops while printing
3.1.7 Mounting holes
Two (2) holes based underneath the printer under the rubber feet.
3.1.8 Sensors
The A630/A631 printer is fitted with two (2) sensors, which detect abnormal conditions:
Door-closed sensor:
End-of-paper (EOP) sensor:
3.2 Choosing the proper location for your printer
The A630/A631 printer may be used in a variety of applications; but, to maintain optimum working
conditions from your unit, the following recommendations should be followed:
Avoid dirty or dusty locations, the risk of water exposure, excessive heat or humidity
(temperature from 5 to 50°C for operating or -20 to 50 for storage) and mechanical stress.
Choose a stable level base on which to place the printer.
Make sufficient space around the printer to ensure comfort while using your printer,
including sufficient access to open the lid while changing paper.
It is recommended to avoid mechanical vibrations