User manual

A630/A631/A632 Printer Series User Manual Page 12 / 63 Reference: FDE 3106894 Issue F
2.2.3 A632 version
The nominal voltage is 12V (operating range: 10.6V – 16V). To power the printer, use a cable able to
handle the max current value and protect the installation by using a 12V/10A max. fuse, suited for
automotive applications.
Note – Axiohm will not provide neither the cable nor the fuse.
2.3 Interface specifications
See chapter "Communications interface connectors".
2.4 Environmental specifications
2.4.1 Environmental conditions
Operating temperature:
5 to 50 °C
Storage temperature: A630/A631
A632
-20 to 50 °C
-20 to 70 °C
Maximum humidity:
10 to 90 % RH (non-condensing)
Vibration
Details upon request : consult AXIOHM's Technical Support
Team.
Drop test
The printer is packed.
1 meter on concrete
1 meter on wood
2.4.2 EMI, ESD and Safety
Conditions of acceptability:
EMI is measured using AXIOHM power supply adapter ref. 3106262. UL valid only if the proper power
supply (AXIOHM part n° 3106175) and the proper batteries (AXIOHM part3106282) are used.
Note
: The available replacement kits are:
ref. 3106935 A630/A631/A632 POWER SUPPLY KIT EU for the power supply
ref. 3106880 BATTERY KIT A631 for the batteries.
Safety recommendations
: The power supply should be installed so it can be accessed in order to enable
power disconnection.
A630/A631 is designed to meet the requirements of:
CE
FCC
C-tick for Australia
UL / cUL
Bluetooth
TM
(These products are in conformity with the 1999-5-CE directives.