Specifications

7193 Service Guide Chapter 3: Diagnostics
August 1998 29
4.
Turn the power back on to enter the settings into the EEROM and enable the Data
Scope Mode.
On remote models, the On Line light (green) blinks.
5.
Turn the power off.
6.
Set the DIP switches to the former settings.
DIP switch 1 must be Off to return the printer to the on-line mode.
7.
Turn the power back on.
The printer is on-line and can communicate with the host computer.
8.
Run a transaction from the host computer.
All commands and data sent from the host computer will be printed as Hex characters
as shown in the following illustration.
Exit the Data Scope Mode
1.
Turn the power off.
2.
Set the switches to the settings in the table.
Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6
On Off Off On Off Off
3.
Turn the power back on to enter the settings into the EEROM and disable the Data
Scope Mode.
On remote models, the On Line light (green) blinks.
4. Turn the power off.
5. Set the DIP switches to the former settings.
DIP switch 1 must be Off to return the printer to the on-line mode.
6. Turn the power back on.
The printer is on-line and can communicate normally with the host computer.