Setting Data Error and Data Buffer options
This function allows you to select the handling of data reception errors (RS-232C only) and
to select the size of the data buffer (RS-232C and Parallel only).
Caution: The DIP switches are pre-set at the factory and should generally not be changed.
If you must change them, do so carefully to avoid changing other functions. Run the print
test to see the current settings for this function. See “Testing The Printer” in chapter 2.
1.
Turn the power off.
2.
Turn the printer over and note what the current DIP switch settings are.
3.
Set the switches to the settings in the table you want for data reception errors and the
data buffer.
Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Option
On Off On Off Off Off
“?” for Data Errors
1, 2
On Off On Off Off On
Ignore Data Errors
2
On Off On Off On Off
4K Byte Data Buffer
1, 3
On Off On Off On On
One Line Data Buffer
3
1
Default
2
RS-232C only
3
RS-232C and Parallel only
Choose one of the Data Errors options and one of the Data Buffer options.
4.
Turn the power back on to enter the settings into the EEROM.
On remote models, the On Line light (green) blinks.
5.
Turn the power off.
6.
Set the DIP switches to the former settings.
DIP switch 1 must be Off to return the printer to the RS-232C .