Specifications

Chapter 2: Installing the Printer 7193 Service Guide
August 199810
LCSIO (RS-485) Switch Settings
For printers using the LCSIO (RS-485) interface, the DIP switches are used to set the LCSIO
(RS-485) address bits as shown in the following table.
DIP Switch 1 (Set to Off when setting address bits)
Off = LCSIO (RS-485) Communication, On-line Mode (Default)
On = Level 1 Diagnostics: Setup Mode
DIP Switch 2 is always Off
Address w/Parity Address
w/o Parity Switch 3 Switch 4 Switch 5 Switch 6
3C BC Off Off Off Off
3D 3D Off Off Off On
3E 3E Off Off On Off
3F BF Off Off On On
40 40 Off On Off Off
41 C1 Off On Off On
42 C2 OffOnOnOff
43 43 Off On On On
44 C4 On Off Off Off
45 45 On Off Off On
46 46 On Off On Off
47 C7 On Off On On
48 C8 On On Off Off
49 49 On On Off On
4A 4A On On On Off
4B CB On On On On