Specifications

7193 Owner’s Guide Chapter 6: Commands
August 1998 81
m Bar Code dn, Length
65 UPC-A 48- 57 (ASCII numerals) Fixed Length: 11, 12
66 UPC-E 48- 57 Fixed Length: 11, 12
67 JAN13 (EAN) 48- 57 Fixed Length: 12, 13
68 JAN8 (EAN) 48- 57 Fixed Length: 7, 8
69 CODE39 48- 57,
65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII
special characters)
d1 = dk = 42 (start/stop code is
supplied by printer if necessary)
Variable
70 Interleaved 2 of 5
(ITF)
48- 57 Variable
(Even Number)
71 CODABAR (NW-7) 65- 68, start code
48- 57,
36, 43, 45, 46, 47, 58
Variable
73 Code 128* 0-105
d1 = 103-105 (must be a Start code)
d2 = 0-102 (data bytes)
(Stop code is provided by the
printer)
Variable
Select Width of Bar Code
Sets the bar code width to n dots or n/152 inch (n/6 mm).
Hexadecimal Decimal ASCII Value of n Default
1D 77 n 29 119 n GS w n
2, 3, 4 3