Safety advices:
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
SPU 58-06 | SPU 512-06
SPU 516-06 | SPU 524-06
SPU 532-06
basic-line
Multiswitches /
Cascade units
Operation instructions
Technical data:
Your device is marked with the WEEE symbol (Waste Electronics and
Electrical Equipment). This means that the electrical and electronic
components must not be disposed of as residual waste. Used electrical and
electronic components must be disposed of separately.
WEEE Nr.
DE26869279
Article SPU 58-06 SPU 512-06 SPU 516-06 SPU 524-06 SPU 532-06
Frequency range (TERR | SAT) 5…862 MHz | 950…2400 MHz
Number of inputs 5
Number of trunk outputs 5
Subscriber ports 8 12 16 24 32
Tap loss TERR 23 dB ±2 dB 27 dB ±3 dB 33 dB ±3 dB
Tap loss SAT -1...-3 dB ±2 dB -1...-2 dB ±2 dB 2...-1 dB ±2 dB
Max. output level subscriber ports SAT
1
102 dBµV
Switch commands 13/18 V, 0/22 kHz
Through loss TERR 2 dB ±1 dB 2…3 dB ±1 dB 2 dB ±2 dB
Through loss SAT 2 dB ±1 dB 2…4 dB ±1 dB 2…6 dB ±2 dB
Isolation V®H. >30 dB
Isolation TERR input®SAT. input 30 dB
Ambient temperature range (acc. to EN 60065) -20…+50°C
Current consumption per subscriber port
(withoutLNB supply)
< 35 mA
Max. LNB supply current 1500 mA
Equipotential bonding connection 4 mm2
Dimensions (W × H × D) appr. 112 x 137 x 63 mm 150 x 137 x 63 mm 240 x 137 x 63 mm
Protection class IP 20
1
3rd order SAT max. EN50083-3 35dB KMA (2 sender test method)