Manual

Table Of Contents
2022-08-16 | Technical improvements, changes in design, printing and other errors reserved. | AXING-BA_EOC-1-2-32.pdf Page 9 of 26
3.1. Connectors and LED indicators on the rear panel
Port Name/Button
Type
Function
A G.hn F EoC signal
B
TV
F
TV signal (use depends on the application (see 4, page 11)
C
2
R Reset button
D
LAN1/LAN2
RJ-45
Connect to PC or STB or other Ethernet devices
E
DC12V
DC
Connect to the power adapter plug
Status
On
Flashing
Off
1
Linked
Receive or transmit
Disconnected or Link fail
2
Linked
Receive or transmit
Disconnected or Link fail
3
1000 Mbps
N/A
100 Mbps
4
Linked
Receive or transmit
Disconnected or Link fail
5
1000 Mbps
N/A
100 Mbps
6
Power supply on
N/A
Power supply off
7
2
WiFi on
Receive or transmit
WiFi off
The colour of the LED 1 (Link/Act | Quality) shows the quality of the EoC connection: Green: High
Orange: Medium
Red: Low
3.2. Power supply
Connect the AC adapter to the DC12V connector and plug the AC adapter into a power outlet.
3.2.1. Notes on the supplied power supply units
Only use the plug-in power supply unit supplied with the device.
The mains socket must be easily accessible. If an operating error occurs, the power supply unit must be
unplugged from the socket immediately. The power supply unit is immediately ready for operation when it is
plugged into the socket. To switch off the mains adapter, it must be pulled out of the socket. Do not pull on
the cable when disconnecting it.
2